4
GB
Installation of the 38 AS wall-mounted
heater
Minimum distances
1. Fasten the wall mounting bracket to the cabin
wall as shown in Figs. 3 + 4, centered above
the fresh-air inlet, using the enclosed tension
plate screws.
2. Connect the power cable as shown in the
circuit diagram. A circuit diagram is provided
on the inside of the terminal box cover.
3. Close the terminal box with the cover, spacer
toward the outside, using 2 sheet metal
screws.
4. Mount the sauna heating unit to the wall
mounting bracket by the mounting slots and
insert the spacer (Fig. 7).
Power input in
kW
Suitable for cabin
size
in m3
Minimum diameters in mm2 (copper lead) for connection to 380-
400 V AC 3N
Heater connection cable
from control unit to heater
Power line from
power grid
to control unit
Fuses (in A)
4,5 ca. 4 - 6 5 x 2,5 5 x 1,5 3 x 16
6,0 ca. 6 - 10 5 x 2,5 5 x 1,5 3 x 16
7,5 ca. 8 - 12 5 x 2,5 5 x 1,5 3 x 16
9,0 ca. 10 - 14 5 x 2,5 5 x 1,5 3 x 16
12,0 ca. 14 - 18 5 x 4 5 x 1,5 (2 Stück) 3 x 25
Table 2
Cabin wall
42 cm
Heater
safety grate
8 cm
36,0 cm
8 cm
Fig. 2
8 cm
Fig. 3
Fresh-air inlet
65 cm
59,5 cm
Wall mounting
bracket
Wall mounting
bracket
m
in
. 10
c
m
34 cm
65 cm
Fresh-air inlet
Fig. 4