5. Secure the sauna heating unit to the wall
mounting bracket by inserting a sheet metal
screw through the hole positioned at the rear
edge of the heater (Fig. 5 and 6).
Sensor installation
The built-in control unit is equipped with a
thermostat and an a temperature limiter. The
capillary tube sensors are delivered with the
heater unit (packed in the lower section of the
heater). The sensor must be removed carefully
from the heater and fixed in position in the
mounting holes on the sensor mounting bracket.
The capillary tubes must not be bent or damaged.
The smallest bending radius should not be less
than 4-5 cm during and after installation.
The sensor mounting bracket is mounted (using
the provided wood screws) to the cabin wall as
shown in Fig. 7, centered above the heater
exhaust outlet facing the cabin door and
positioned 25 cm below the cabin ceiling, The
bracket must be placed in this position, as
otherwise the desired temperatures cannot be
achieved. The capillary tubes can be fastened
to the cabin wall with the fastening elements
provided. The excess length of capillary tube
should be rolled up behind the heater and must
not be pushed back into the connection box
under any circumstances.
If the installed capillary tubes do not have an
insulating mantle, they must be protected against
contact. This can be accomplished by running
the tubes through the grooves in the wall paneling
and covering them with appropriate wood
molding.
Installation by a qualified electrician
1.) Drill a hole measuring approx. 10 cm in
diameter in the cabin wall at the point where
the main power cable is to be inserted. Run
the cable through the hole toward the outside
of the sauna cabin and connect it to the main
power line in a distributor box suitable for
use in moist environments.
This operation must be performed in accordance
with the wiring diagram (Fig. 1), the circuit
diagram on the control panel and the regulations
of the local EVU and the VDE.
Caution! The local site installation must provide
for sufficient fuse capacity and an emergency
power cut-off switch.
Fig.6
Securing
screw
Fig. 5
18 cm
20 cm
25 cm
Fiig. 7
Please remember that the sensor lines are thin,
flexible tubes that must not be squeezed or
subjected to pressure.
These lines must never be cut, as this will
destroy the components.
Fig. 8
Power cable
Distributor box
Fresh-air
inlet
suitable for
use in moist
environments